Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Rev. clín. periodoncia implantol. rehabil. oral (Impr.) ; 9(2): 132-139, ago. 2016. ilus, tab, graf
Article in English | LILACS | ID: lil-794508

ABSTRACT

Aim To evaluate the release of sodium hypochlorite from three different commercial brands of heat-polymerized acrylic resin immersed in water and submitted to mechanical or chemical polishing after disinfection with hypochlorite at different concentrations. Material and methods Fifty-four disk-shaped specimens (n = 18) were made for each resin (Lucitone 550, QC-20, and Classico) and assigned to two groups according to the type of polishing. Specimens were divided in three sub-groups in relation to sodium hypochlorite concentration (1%, 2.5%, and 5.25%), and the groups were immersed for 10-min periods in each sodium hypochlorite concentration. The electrochemical method used for detecting the release of sodium hypochlorite in each specimen was the cyclic voltammetry. Results In the specimens of Clássico resin polished mechanically and immersed in 5.25% sodium hypochlorite, as well as Lucitone and QC-20 resins immersed in 2.5%, the amounts of disinfectant solution released in the four 15-min water exchanges were higher than the four 60-min exchanges. Conclusion There were differences in hypochlorite release from the three commercial brands of denture-base acrylic resins subjected to mechanical polishing. However, no hypochlorite release from the same resins was observed when they were subjected to chemical polishing.


Objetivo Evaluar la liberación de hipoclorito de sodio de 3 marcas comerciales diferentes de resinas termo-polimerizadas sumergidas en agua, y sometidas a pulido mecánico o químico después de la desinfección con hipoclorito a diferentes concentraciones. Material y métodos Cincuenta y cuatro especímenes en forma de disco (n = 18) fueron confeccionados para cada resina (Lucitone 550, QC-20 y Clássico) y asignados a 2 grupos de acuerdo con el tipo de pulido. Las muestras se dividieron en 3 subgrupos en relación con la concentración de hipoclorito de sodio (1, 2,5 y 5,25%), y los grupos se sumergieron durante períodos de 10 min en cada concentración de hipoclorito de sodio. El método electroquímico usado para la detección de la liberación de hipoclorito de sodio en cada espécimen fue a través de voltametría cíclica. Resultados En las muestras pulidas mecánicamente de resina Clássico inmerso en hipoclorito de sodio al 5,25%, así como en las resinas Lucitone y QC-20 inmersas a 2,5%, la cantidad de solución desinfectante liberada en los 4 intercambios de agua de 15 min fue superior a los 4 de 60 min. Conclusión Hubo diferencias en la liberación de hipoclorito de las 3 marcas comerciales de resinas acrílicas sometidas a pulido mecánico. Sin embargo, no se observó liberación de hipoclorito en las mismas resinas cuando se sometieron a pulido químico.


Subject(s)
Humans , Resins, Synthetic , Sodium Hypochlorite/chemistry , Dentures , Dental Disinfectants/chemistry , Time Factors , Acrylic Resins
2.
Int. j. odontostomatol. (Print) ; 9(3): 437-442, dic. 2015. ilus
Article in English | LILACS | ID: lil-775468

ABSTRACT

The purpose of this study was to evaluate through finite element analysis (FEA) the total deformation or displacement as a whole system of multiple implant-supported prostheses in the maxillary anterior region with different implant's length, connection, location and restoration material. An edentulous anterior region of a hemi-maxilla model was used in finite element analysis. The simulations were divided in two groups according to treatment plan: 1) two implants were placed in the upper central incisors, simulating an implant-supported fixed prosthesis (acrylic resin and metal-ceramic) of four elements with cantilever of both upper lateral incisors; 2) two implants placed in the upper lateral incisors, simulating a conventional fixed prosthesis of four elements with both upper central incisors as pontic. Models with cantilever prosthesis in acrylic resin showed the highest values of total deformation, which were 17 times higher than those of metal-ceramic in the distal face of the lateral incisors, regardless of the type of implant connection. In conventional prostheses in acrylic resin, external hexagon connections had lower total deformation values compared with morse taper connection. Also, the implant length was found to have no effect on the values of total deformation. In conclusion, total deformation was substantially greater in all models with acrylic resin restorations.


El propósito de este estudio fue evaluar mediante análisis de elementos finitos (FEA) la deformación total o desplazamiento como un sistema completo de prótesis múltiples implanto-soportadas en la región anterior de la maxila con diferentes longitudes, conexiones y posiciones del implantes y variando el material de restauración. Se utlizó un modelo hemi-maxilar de una región anterior desdentada de un modelo para ser analizado por medio de elementos finitos. Las simulaciones fueron divididas en dos grupos de acuerdo con el plan de tratamiento: 1) dos implantes se colocaron en los incisivos centrales superiores, simulando una prótesis fija implanto-soportada (resina acrílica y metal-cerámica) de cuatro elementos con cantilever de ambos incisivos laterales superiores; 2) dos implantes colocados en los incisivos laterales superiores, simulando una prótesis fija convencional de cuatro elementos con los dos incisivos centrales superiores como póntico. Los modelos con prótesis en cantilever en resina acrílica mostraron los mayores valores de deformación total, siendo 17 veces mayor a los de metal-cerámica en la cara distal de los incisivos laterales, independientemente del tipo de conexión del implante. En las prótesis convencionales en resina acrílica, las conexiones hexagonales externas tenían valores deformación total más bajos en comparación con la conexión cono morse. También, se encontró que la longitud del implante no mostró ninguna influencia en los valores de la deformación total. En conclusión, la deformación total fue sustancialmente mayor en todos los modelos con restauraciones de resina acrílica.


Subject(s)
Humans , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Finite Element Analysis , Stress, Mechanical , Computer Simulation , Imaging, Three-Dimensional , Dental Stress Analysis , Models, Theoretical
3.
Int. j. morphol ; 33(4): 1377-1379, Dec. 2015. ilus
Article in English | LILACS | ID: lil-772325

ABSTRACT

To validate the virtual finite element analysis (FEA) results, it is needed that the mathematical models take into account the insertion area. Thus, the aim of this study was to measure the insertion area of masticatory muscles in the mandible in human cadavers to be used in FEA. The insertion area of the masticatory mandible's muscles was measured on both sides of fifty human cadavers throughout digital photos and software. The insertion area of the masseter was 7.47(±0.41) cm2, the temporal (inner portion) was 3.05(±0.13) cm2, the temporal (outer portion) was 2.25(±0.28) cm2, the medial pterygoid was 2.2(±0.23) cm2, and the lateral pterygoid was 0.8(±0.05) cm2. In conclusion, there is enough data to be used for the finite element analysis.


Para validar los resultados virtuales de análisis por elementos finitos (FEA) es necesario que los modelos matemáticos consideren el área de inserción muscular. Así, el objetivo de este estudio fue medir el área de inserción en la mandíbula de los músculos de masticación en cadáveres humanos para ser utilizado en FEA. El área de inserción en la mandíbula de los músculos de masticación fue medida en ambos lados de cincuenta cadáveres humanos por medio de fotografías digitales y software. El área de inserción del músculo masetero fue 7,47(±0,41) cm2, la porción interna del músculo temporal fue de 3,05(±0,13) cm2 y su porción externa de 2,25(±0,28) cm2, para los músculos pterigoideo medial fue de 2,2(±0,23) cm2 y pterigoideo lateral 0,8(±0,05) cm2. En conclusión, los datos son suficientes para ser utilizados para análisis de elementos finitos.


Subject(s)
Humans , Mandible/anatomy & histology , Masticatory Muscles/anatomy & histology , Cadaver , Finite Element Analysis
4.
Article in Spanish | LILACS | ID: lil-734833

ABSTRACT

OBJETIVO Comparar la fuerza máxima de mordida (FMM) de los pacientes adultos mayores portadores de prótesis parciales removibles con extremo libre bilateral (clase I Kennedy) maxilar y mandibular, en individuos mapuches y no mapuches durante 2 períodos diferentes de medición. PACIENTES Y MÉTODOS Se dividió a 40 sujetos cuyas edades fluctuaban entre 60 y 80 años en 2 grupos de acuerdo con su origen étnico para medir su FMM en la región de molares a través de un dispositivo hidráulico. Los sujetos fueron instruidos para realizar 3 mordidas por lado lo más fuerte posible y el valor más alto fue considerado como fuerza máxima. Los datos fueron analizados por medio del test t de Student y prueba de Levene. RESULTADOS El género masculino presentó mayores valores de FMM (p < 0,05). Además, el grupo de individuos de etnia mapuche presentó mayores valores de FMM (p < 0,05). Se identificaron valores de FMM considerablemente mayores en el período de un mes posterior a la inserción de la nueva prótesis (p < 0,05). CONCLUSIONESLos mayores valores de FMM fueron observados en la etnia mapuche, en individuos de género masculino y un mes posterior a la inserción de ambas prótesis.


OBJECTIVE To compare the maximum bite force (FMM), in two different measurement periods, of mapuche and non-mapuche elderly patients with both maxillary and mandibular Kennedy class I removable partial dentures. PATIENTS AND METHODS A total of 40 subjects with ages ranging between 60 and 80 years were divided into 2 groups according to their ethnic origins to measure FMM in the molar region using a hydraulic device. The subjects were instructed to perform three bites with each side as hard as possible, and the highest value was considered as the maximum force. Data were analyzed by Student's t- test and Levene test. RESULTS Male gender showed higher FMM values (p < 0.05). The group of mapuche individuals showed the highest values of FMM (p < 0.05). Finally, considerably higher FMM values were identified at one-month period subsequent to the insertion of the new prosthesis (p < 0.05). CONCLUSIONS The highest FMM values were observed in patients of mapuche ethnic origin, in male patients, and at one-month period after both prostheses were inserted.


Subject(s)
Humans , Male , Bite Force , Indians, South American , Denture, Partial, Removable , Chile
5.
RGO (Porto Alegre) ; 62(2): 173-175, Apr-Jun/2014. graf
Article in English | LILACS | ID: lil-725590

ABSTRACT

The oral rehabilitation can be made with several ways with the objective to reestablish the masticatory function and the esthetic of the patient. The aim of this clinical case is to present a different type of fixed partial denture, as alternative option to the dental surgeon, showing particularities like indications, contraindications, advantages, disadvantages and technical procedures necessary to its fabrication. The sequential presentation of the realized procedures emphasized the unique aspects of the dental preparation, impression techniques, and cautions during metal structures and ceramic try-in procedures, and esthetic overlay on the metal with composite resin. As a result, it could be observed that the ultraconservative fixed partial denture required lesser removal dental structure, re-established the esthetic and the occlusion of the patient. Finally, it can be concluded that the ultraconservative fixed partial denture is a treatment option to be used in the small prosthetic space with success both mechanically and esthetically.


A reabilitação oral pode ser realizada de diversas formas com o intuito de restabelecer a função mastigatória e a estética do paciente. Este caso clínico tem o objetivo de apresentar um tipo diferente de prótese parcial fixa, como opção alternativa para o cirurgião-dentista, mostrando suas particularidades quanto à indicação, contraindicação, vantagens, desvantagens e procedimentos necessários à sua elaboração. A apresentação sequencial dos procedimentos realizados ressaltou os aspectos únicos do preparo dental, da técnica de moldagem, dos cuidados a serem observados na prova da estrutura metálica, na prova da cerâmica, dos aspectos diferenciais na cimentação e do recobrimento estético da estrutura metálica com resina composta. Como resultado pode-se observar que a prótese ultraconservadora exigiu menor desgaste estrutural dos dentes pilares, restabeleceu a estética e a oclusão do indivíduo. Diante disso, pode-se concluir que a prótese parcial fixa ultraconservadora é uma opção de tratamento a ser utilizada em pequenos espaços protéticos com sucesso mecânico e estético.

6.
Int. j. odontostomatol. (Print) ; 8(1): 133-139, Apr. 2014. ilus, tab
Article in English | LILACS | ID: lil-711558

ABSTRACT

This study evaluated the fracture resistance of maxillary premolars with wide Mesial-Occlusal-Distal (MOD) cavity preparations and unsupported cusps restored by four ways, compared with intact teeth. Thirty five human teeth were divided into five groups: control (G1 - intact teeth) and four experimental groups of MOD-prepared teeth: with buccal (B) and lingual (L) cusps reinforced with composite (Z-250) and restored with silver amalgam (Permite C) (G2); teeth with B and L cusps reinforced and linked with composite (P-60) and restored with silver amalgam (Permite C) (G3); teeth restored with composite (Z-250) by incremental fill technique (G4); and teeth with B and L cusps reinforced and linked with composite (P-60) and restored with composite (Z-250) by incremental fill technique (G5). After thermal cycling (500 cycles, 5°C to 55°C), fracture resistance was tested in a universal testing machine. Statistical analysis of the results (ANOVA) revealed no significant difference (p>0.5) among the groups (G1=157.78Kgf, G2=183.99Kgf, G3=152.53Kgf, G4=182.61Kgf and G5=155.96Kgf). Visual analysis of the teeth tested showed predominance of oblique failure pattern. The four types of restoration evaluated provide fracture resistance with values equivalent to intact teeth in MOD-prepared intact teeth with parallel walls and composite-reinforced cusps


Se evaluó la resistencia a la fractura de los premolares maxilares con preparaciones amplias de cavidades Mesio-Ocluso-Distal (MOD) y cúspides sin soporte restauradas por medio de cuatro formas, en comparación con dientes intactos. Treinta y cinco dientes humanos se dividieron en cinco grupos: control (G1 - dientes intactos) y cuatro grupos experimentales preparados con cavidades MOD: con cúspides bucales (B) y linguales (L) reforzadas con resina compuesta (Z-250) y restaurada con amalgama de plata (Permite C) (G2); dientes concúspides B y L reforzadas y unidas con composite (P-60) y restaurado con amalgama de plata (Permite C) (G3); dientes restaurados con composite (Z-250) a través de la técnica incremental (G4), y dientes con cúspides B y L reforzadas y unidas con resina compuesta (P-60) y restauradas con composite (Z-250) mediante la técnica incremental (G5). Después del ciclado térmico (500 ciclos, 5°C a 55°C), la resistencia a la fractura fue probada en una máquina de ensayo universal. El análisis estadístico de los resultados (ANOVA) no reveló diferencias significativas (p> 0,5) entre los grupos (G1 = 157,78 Kgf, G2 = 183,99 Kgf, G3 = 152,53 Kgf, G4 = 182,61 Kgf y G5 = 155,96 Kgf). El análisis visual de los dientes probados mostró un predominio de patrón de falla oblicua. Los cuatro tipos de restauración evaluados proporcionaron resistencia a fractura con valores equivalentes a los dientes intactos con preparaciones MOD, paredes paralelas y cúspides reforzadas con resina compuesta


Subject(s)
Humans , Tooth Fractures , Composite Resins/chemistry , Dental Amalgam/chemistry , Dental Stress Analysis , Stress, Mechanical , Bicuspid , Analysis of Variance , Materials Science
7.
Braz. dent. j ; 24(6): 630-634, Nov-Dec/2013. graf
Article in English | LILACS | ID: lil-697662

ABSTRACT

This study evaluated the tensile and flexural strength of tungsten inert gas (TIG) welds in specimens made of commercially pure titanium (CP Ti) compared with laser welds. Sixty cylindrical specimens (2 mm diameter x 55 mm thick) were randomly assigned to 3 groups for each test (n=10): no welding (control), TIG welding (10 V, 36 A, 8 s) and Nd:YAG laser welding (380 V, 8 ms). The specimens were radiographed and subjected to tensile and flexural strength tests at a crosshead speed of 1.0 mm/min using a load cell of 500 kgf applied on the welded interface or at the middle point of the non-welded specimens. Tensile strength data were analyzed by ANOVA and Tukey's test, and flexural strength data by the Kruskal-Wallis test (α=0.05). Non-welded specimens presented significantly higher tensile strength (control=605.84±19.83) (p=0.015) and flexural strength (control=1908.75) (p=0.000) than TIG- and laser-welded ones. There were no significant differences (p>0.05) between the welding types for neither the tensile strength test (TIG=514.90±37.76; laser=515.85±62.07) nor the flexural strength test (TIG=1559.66; laser=1621.64). As far as tensile and flexural strengths are concerned, TIG was similar to laser and could be suitable to replace laser welding in implant-supported rehabilitations.


Este estudo avaliou a resistência à tração e à flexão de soldas feitas com gás inerte de tungstênio (TIG) em amostras de titânio comercialmente puro (Ti CP) em comparação com a solda a laser. Sessenta amostras cilíndricas (diâmetro de 2 mm e espessura de 55 mm) foram distribuídas aleatoriamente em três grupos para cada ensaio (n=10): sem solda (controle), solda TIG (10V, 36A, 8 s) e solda com laser de Nd:YAG (380 V, 8 ms). As amostras foram radiografadas e submetidas aos testes de resistência à tração e à flexão em máquina de ensaios mecânicos à velocidade de 1mm/min com célula de carga de 500 kgf aplicada na interface soldada ou no ponto médio das amostras controle. Os dados de resistência à tração foram analisados estatisticamente por ANOVA e teste de Tukey e os dados de resistência à flexão pelo teste de Kruskal-Wallis (α=0,05). Espécimes não-soldados apresentaram resistência à tração (controle=605,84±19,83) (p=0,015) e resistência à flexão (controle=1908,75) (p=0,000) significantemente maiores que os solados com TIG ou laser. Não houve diferença estatisticamente significante (p>0.05) entre os tipos de solda no teste de resistência à tração (TIG=514,90±37,76; laser=515,85±62,07) nem no teste de resistência à flexão (TIG=1559,66; laser=1621,64). As resistências à tração e à flexão foram similares quando as amostras foram soldadas com TIG e a laser.


Subject(s)
Lasers , Tungsten , Titanium/chemistry , Welding/methods , Porosity , Shear Strength , Tensile Strength
8.
Braz. oral res ; 25(2): 143-149, Mar.-Apr. 2011. ilus, tab
Article in English | LILACS | ID: lil-583861

ABSTRACT

The purpose of this study was to evaluate the dentin shear bond strength of four adhesive systems (Adper Single Bond 2, Adper Prompt L-Pop, Magic Bond DE and Self Etch Bond) in regards to buccal and lingual surfaces and dentin depth. Forty extracted third molars had roots removed and crowns bisected in the mesiodistal direction. The buccal and lingual surfaces were fixed in a PVC/acrylic resin ring and were divided into buccal and lingual groups assigned to each selected adhesive. The same specimens prepared for the evaluation of superficial dentin shear resistance were used to evaluate the different depths of dentin. The specimens were identified and abraded at depths of 0.5, 1.0, 1.5 and 2.0 mm. Each depth was evaluated by ISO TR 11405 using an EMIC-2000 machine regulated at 0.5 mm/min with a 200 Kgf load cell. We performed statistical analyses on the results (ANOVA, Tukey and Scheffé tests). Data revealed statistical differences (p < 0.01) in the adhesive and depth variation as well as adhesive/depth interactions. The Adper Single Bond 2 demonstrated the highest mean values of shear bond strength. The Prompt L-Pop product, a self-etching adhesive, revealed higher mean values compared with Magic Bond DE and Self Etch Bond adhesives, a total and self-etching adhesive respectively. It may be concluded that the shear bond strength of dentin is dependent on material (adhesive system), substrate depth and adhesive/depth interaction.


Subject(s)
Humans , Acid Etching, Dental/methods , Dental Bonding/methods , Dentin-Bonding Agents/chemistry , Dentin/chemistry , Analysis of Variance , Bisphenol A-Glycidyl Methacrylate/chemistry , Dental Cements/chemistry , Dentin/ultrastructure , Materials Testing , Organophosphates/chemistry , Resin Cements/chemistry , Shear Strength , Surface Properties
9.
Braz. dent. j ; 22(6): 490-496, 2011. ilus, tab
Article in English | LILACS | ID: lil-622723

ABSTRACT

This study evaluated the release of glutaraldehyde from heat-polymerized acrylic resins subjected to disinfection followed by chemical and mechanical polishing. Ninety disc-shaped specimens (15 x 4 mm), 30 per resin (Lucitone 550, QC-20 and Classico), were made and assigned to 2 groups according to the type of polishing. One side of each specimen was not polished and the other was either mechanically (n=45) or chemically (n=45) polished, and immersed in water at 50°C for 1 h to allow the release of intrinsic substances and then kept in distilled water for 7 days. The specimens were disinfected by immersion in 2% glutaraldehyde for 10 min. After this period, 3 specimens from each group were immersed in water for 15, 30, 60, 120 and 240 min. For the 15-, 30-, 60-min immersions, 4 water exchanges were done at the end of period. High performance liquid chromatography (HPLC) was used to detect and quantify the glutaraldehyde released after each period. Data were analyzed statistically by two-way ANOVA and multiple comparisons were done by Tukey’s and Scheffé’s tests (α=0.05). No glutaraldehyde release was observed from the specimens with chemical polishing at any of the immersion periods, while the mechanically polished specimens released glutaraldehyde. In the groups with water exchanges, Lucitone released more disinfectant in the 15-min period (0.040 μg/mL), Classico in the 30-min (0.021 μg/mL) and 60-min (0.018 μg/mL) periods, and QC-20 the same amount (-1.760 μg/mL) in all periods. In the groups without water exchanges, Lucitone released the highest amount of disinfectant (-1.370 μg/mL), differing significantly from QC-20 (0022 g/mL) and Classico (0019 g/mL), which were similar. The findings of this showed that chemically polished specimens from the 3 resin brands did not release glutaraldehyde after different periods of immersion, while glutaraldehyde release was observed from the mechanically polished specimens, especially from those made of Lucitone resin.


Este estudo determinou a liberação de glutaraldeído de resinas acrílicas termopolimerizáveis submetidas a polimento químico e mecânico e desinfetadas. Noventa corpos-de-prova circulares (15 x 4 mm), 30 de cada tipo de resina (Lucitone, QC-20 e Clássico), foram confeccionados e divididos em 2 grupos referentes ao tipo de polimento. Um dos lados de cada corpo-de-prova não foi polido e o outro foi polido mecanicamente (n=45) ou quimicamente (n=45), e imersos em água aquecida a 50°C por 1 h para liberação de substâncias intrínsecas e mantidos em água destilada por 7 dias. A seguir era realizada a desinfecção por imersão em solução de glutaraldeído a 2% por 10 min. Decorrido este período, três corpos-de-prova de cada grupo eram imersos em água por 15, 30, 60, 120 e 240 min. Nos períodos de 15, 30 e 60 min foram realizadas até 4 trocas de água após cada período. As amostras eram analisadas por meio de cromatografia líquida de alta eficiência (HPLC) após cada período. Os dados foram analisados estatisticamente pela Análise de Variância e testes complementares de Tukey e Scheffé (α=0,05). Os corpos-de-prova com polimento químico, de todas as marcas comerciais de resina, não liberaram glutaraldeído em qualquer um dos períodos de imersão em água, enquanto os com polimento mecânico liberaram. Nos grupos com trocas de água, a resina Lucitone liberou maior quantidade de desinfetante nas trocas de 15 min (0,040 μg/mL), a resina Clássico nas de 30 (0,021 μg/mL) e 60 min (0,018 μg/mL) e a QC-20 liberou a mesma quantidade (-1,760 μg/mL), em todos os períodos de imersão em água. Nos grupos sem trocas de água, a resina Lucitone liberou maior quantidade de desinfetante (-1,370 μg/mL), sendo diferente estatisticamente das resinas QC-20 (0,022 μg/mL) e Clássico (0,019 μg/mL), que são similares. Pelos resultados conclui-se que corpos-de-prova polidos quimicamente, das três marcas comerciais de resina, não liberaram glutaraldeído após os diferentes períodos de imersão. Contudo, nos corpos-de-prova polidos mecanicamente houve liberação do desinfetante, com Lucitone liberando maior quantidade em relação às demais resinas estudadas.


Subject(s)
Humans , Acrylic Resins/chemistry , Dental Disinfectants/chemistry , Dental Materials/chemistry , Dental Polishing/methods , Disinfection/methods , Glutaral/chemistry , Chromatography, High Pressure Liquid , Dental Polishing/instrumentation , Hot Temperature , Immersion , Materials Testing , Methylmethacrylate/chemistry , Polymerization , Polymethyl Methacrylate/chemistry , Temperature , Time Factors , Water/chemistry
10.
J. appl. oral sci ; 18(5): 487-492, Sept.-Oct. 2010. graf
Article in English | LILACS | ID: lil-564183

ABSTRACT

The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE: This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. MATERIAL AND METHODS: 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). RESULTS: Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. CONCLUSION: Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values.


Subject(s)
Chromium Alloys/chemistry , Dental Casting Technique , Denture Retention , Titanium/chemistry , Dental Casting Investment , Dental Clasps , Denture, Partial, Removable , Materials Testing , Porosity , Pressure , Surface Properties , Time Factors , Vacuum
11.
Int. j. morphol ; 28(3): 743-748, Sept. 2010. ilus
Article in English | LILACS | ID: lil-577179

ABSTRACT

Distraction osteogenesis is a technique for induction of new bone formation between two segments of a bone that presents wide possibilities of use in Dentistry. However, the available information on this subject is still scarce. The aim of this article is to review the literature related to bone formation, mechanically induced by distraction osteogenesis, in order to supply subsidies the agreement of this process.


La distracción osteogénica es una técnica para la inducción de la formación de nuevo hueso entre dos segmentos de un hueso que presenta amplias posibilidades de uso en Odontología. Sin embargo, la información disponible sobre este tema es aún escasa. El objetivo de este artículo es revisar la literatura relacionada con la formación de hueso, mecánicamente inducida por la distracción osteogénica, con el fin de proveer una contribución de acuerdo a este proceso.


Subject(s)
Humans , Osteogenesis, Distraction , Dentistry/methods , Bone Regeneration/physiology , Biomechanical Phenomena
12.
Braz. dent. j ; 21(3): 241-246, 2010. tab
Article in English | LILACS | ID: lil-556825

ABSTRACT

Prosthetic restorations that have been tried in the patient's mouth are potential sources of infection. In order to avoid cross-infection, protocols for infection control should be established in dental office and laboratory. This study evaluated the antimicrobial efficacy of disinfectants on full metal crowns contaminated with microorganisms. Full crowns cast in a Ni-Cr alloy were assigned to one control group (n=6) and 5 experimental groups (n=18). The crowns were placed in flat-bottom glass balloons and were autoclaved. A microbial suspension of each type of strain - S. aureus, P. aeruginosa, S. mutans, E. faecalis and C. albicans- was aseptically added to each experimental group, the crowns being allowed for contamination during 30 min. The contaminated specimens were placed into recipients with the chemical disinfectants (1 percent and 2 percent sodium hypochlorite and 2 percent glutaraldehyde) for 5, 10 and 15 min. Thereafter, the crowns were placed into tubes containing different broths and incubated at 35ºC. The control specimens were contaminated, immersed in distilled water for 20 min and cultured in Thioglycollate broth at 35ºC. Microbial growth assay was performed by qualitative visual examination after 48 h, 7 and 12 days. Microbial growth was noticed only in the control group. In the experimental groups, turbidity of the broths was not observed, regardless of the strains and immersion intervals, thus indicating absence of microbial growth. In conclusion, all chemical disinfectants were effective in preventing microbial growth onto full metal crowns.


Restaurações protéticas provadas na cavidade bucal dos pacientes são fontes potenciais de infecção. Para evitar infecção cruzada, protocolos de controle de infecção devem ser estabelecidos no consultório e laboratório odontológicos. Este estudo avaliou a eficácia antimicrobiana de desinfetantes químicos em coroas metálicas contaminadas com microorganismos. Coroas totais fundidas com liga de Ni-Cr foram divididas em grupo controle (n=6) e 5 grupos experimentais (n=18). As coroas foram colocadas em balões de vidro e esterilizadas em autoclave. A suspensão microbiana de cada tipo de cepa (S. aureus, P. aeruginosa, S. mutans, E. faecalis e C. albicans) foi assepticamente adicionada a cada grupo experimental, e as coroas foram deixadas contaminar por 30 min. Os corpos-de-prova contaminados foram colocados em recipientes com os desinfetantes químicos (hipoclorito de sódio 1 por cento e 2 por cento e glutaraldeído) por 5, 10 e 15 min. A seguir, as coroas foram colocadas em tubos contendo diferentes meios de cultura e incubadas a 35ºC. Os corpos-de-prova do grupo controle foram contaminados, imersos em água destilada por 20 min e a seguir colocados em tubos de ensaio com meio de cultura Thioglycollate e incubados a 35ºC. A análise do crescimento microbiano foi realizada pelo exame visual qualitativo após 48 h, 7 e 12 dias. Houve crescimento microbiano apenas no grupo controle. No grupo experimental não foi observada turvação dos meios de cultura, independentemente das cepas e períodos de imersão. Conclui-se que todos desinfetantes químicos foram eficazes para prevenir o crescimento microbiano.


Subject(s)
Humans , Anti-Infective Agents/pharmacology , Crowns/microbiology , Decontamination/methods , Dental Disinfectants/chemistry , Cross Infection/prevention & control , Dental Alloys , Equipment Contamination , Glutaral/pharmacology , Sodium Hypochlorite/pharmacology
13.
Braz. j. oral sci ; 7(26): 1580-1584, July-Sept. 2008. tab
Article in English | LILACS, BBO | ID: lil-521320

ABSTRACT

Aim: The aim of this study was to assess the flexural resistance and color alterations of microwave-polymerized acrylic resins immersed in denture cleansers for different periods of time. Methods: Forty-five rectangular specimens (65x10x3mm) of each commercial brand of the microwave-activated acrylic resins (Vipi Wave and Onda Cryl) were divided in three denture cleanser groups (Bony Plus, Corega Tabs and Efferdent Plus) and a control group (immersion in water). Soaking trials of 15 min and 8 h simulated 30 days of use. The flexural strength test was carried out in a universal testing machine. Color alterations were assessed by visual inspection of photographs. The results obtained in the flexural test, in kgf, were converted to MPa and these values were submitted to analysis of variance with a 5% significance level. Results: There were no significant differences (p<0.05) between Onda Cryl (85.61±12.76) and Vipi Wave (89.8±19.95) after the soaking trials regarding the use of different denture cleansers. No differences were found in relation to the solutions [Bony Plus (88.52±9.89), Corega Tabs (88.75±12.71) and Efferdent (85.86±12.11)], soaking periods [control (87.17±12.92), 15 min (88.05±11.74) and 8 h (87.91±10.30)], and interactions during the 30 days of simulated use. Visual inspection did not detect any color alterations. Conclusions: Denture cleansers, when used according to the manufacturers’ instructions, did not cause any mechanical or visual alterations in the microwave-polymerized acrylic resins after a simulated period of 30 days of use.


Subject(s)
Acrylic Resins , Denture Cleansers , Denture, Complete , Denture Cleansers/chemistry
14.
RGO (Porto Alegre) ; 54(3): 261-264, set.-out. 2006. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-457232

ABSTRACT

O objetivo deste estudo foi avaliar a ação de três agentes isolantes aplicados sobre a superfície de núcleos metálicos fundidos para a confecção de coroas provisórias e a sua influência na fixação com diferentes agentes cimentantes temporários. A partir de uma matriz foram confeccionados 45 padrões em resina acrílica autopolimerizável (Duralay), fundidos com liga de cobre-alumínio (Novelli) e divididos em 9 grupos (n=5). Os núcleos foram isolados com saliva artificial (grupo controle), gel aquoso à base de glicerina (K-Y®) ou vaselina pastosa (Rioquímica), e a seguir confeccionadas as coroas provisórias em resina acrílica autopolimerizável (Vipiflash). Os núcleos eram posicionados em um dispositivo e realizada a cimentação das coroas, com carga padronizada de 300g, com os cimentos Dycal, Provicol e Temp bond. Removidos os excessos, as amostras foram armazenadas em água destilada a 37°C por 40 horas; após esse período foi realizado o ensaio de tração em uma máquina universal EMIC-DL2000 (velocidade = 5mm/minuto e célula de carga = 50 Kgf). A análise de variância evidenciou diferenças estatisticamente significantes para os fatores individuais (p≤0,0l) e para a interação (p≤0,05). Os testes complementares de Tukey e Scheffé indicaram diferenças entre os três agentes isolantes (saliva=8,73; K-Y®= 7,03 e Vaselina= 6,26) e para os cimentos a diferença entre o par formado por Temp Bond/Dycal e Provicol, respectivamente 8.47, 7.60 e 5.95 Kgf. Pelos resultados conclui-se que a saliva deve ser o agente isolante usado na confecção de coroas provisórias a serem cimentadas com Dycal ou Temp bond.


Subject(s)
Cementation , Dental Cements , Denture, Partial, Fixed , Dental Restoration, Temporary
15.
Braz. dent. j ; 16(2): 124-128, maio-ago. 2005. ilus
Article in English | LILACS | ID: lil-413411

ABSTRACT

O objetivo deste estudo foi avaliar a resistência à flexão e alterações de cor de resinas acrílicas termopolimerizáveis imersas em higienizadores de prótese por diferentes períodos de tempo. Corpos-de-prova retangulares (65x10x3mm) de três resinas acrílicas (Lucitone 550, QC-20 e Triplex) foram divididos em três grupos de higienizadores de prótese (Bony Plus, Corega Tabs e Efferdent Plus) e um grupo controle (imersão em água). Foram realizadas imersões por 15 min e 8 horas, simulando 30 dias de uso. O teste de resistência à flexão foi realizado com 105 corpos-de-prova em máquina de ensaios universais. Alterações de cor foram avaliadas por meio de fotografias tiradas de 21 corpos-de-prova. Os resultados de resistência à flexão (em MPa) foram submetidos à análise de variância e teste de Tukey, com nível de significância de 5%. Houve diferenças significantes (p<0.01) entre as resinas Lucitone (89,439 ± 7,962); Triplex (88,024 ± 5,167) and QC-20 (83,379 ± 7,153). Não foram encontradas diferenças significantes (p>0.05) entre os higienizadores de prótese (Bony Plus = 87,693 ± 6,943; Corega Tabs = 86,955 ± 7,114; Efferdent Plus = 86,195 ± 7,865; e controle = 86,536 ± 7.012) nem entre os períodos de imersão (15 min = 86,875 ± 7,625 e 8 h = 87,432 ± 7,355) durante os ciclos de imersão que simularam 30 dias de uso. A inspeção visual não detectou qualquer alteração de cor. Os achados desse estudo revelaram que os higienizadores de prótese, quando usados de acordo com as instruções dos fabricantes, não afetaram a resistência à flexão nem causaram alterações de cor nas resinas acrílicas termopolimerizáveis após um período de uso simulado de 30 dias.


Subject(s)
Humans , Acrylic Resins/chemistry , Denture Bases , Denture Cleansers/chemistry , Color , Dental Stress Analysis/instrumentation , Hot Temperature , Immersion , Materials Testing , Pliability , Polymers/chemistry , Stress, Mechanical , Time Factors , Water/chemistry
16.
J. bras. ortodon. ortop. facial ; 9(50): 136-144, mar.-abr. 2004. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-405758

ABSTRACT

Este estudo foi realizado com o objetivo de investigar a atividade eletromiográfica (EMG) dos músculos temporal (porção anterior) e masseter em portadores de má-oclusão Classe II de Angle, durante tratamento ortopédico funcional com a técnica Reabilitação Dinâmica e Funcional doa Maxilares (RDFM). Foram avaliados dez pacientes com dentição mista, na faixa etária de seis a doze anos (média 8,6), nas condições experimentais: 1) Apertamento em Máxima Intercuspidação Habitual (AMIH); 2)Apertamento Molar Bilateral com Rolete de Algodão (AMBA); 3)Apertamento Máximo com Aparelho (AAPA); e 4) Mastigação Habitual (MH). Os registros eletromiográficos foram executados no ato da instalação da aparatologia, após seis meses e um ano de tratamento com eletrodos bipolares de superfície posionados bilateralmente na porção anterior do músculo temporal e no músculo masseter. As atividades médias dos músculos estudados foram analisadas estatisticamente pela Análise de Variância e teste complementar de Tukey. Pelos resultados concluiu-se que: as funções estudadas mostraram aumento significativo na atividade muscular após um ano de tratamento; não houve diferença estatística entre as condições AMIH, AMBA e AAPA, porém estas foram significativamente diferentes da MH; e a atividade EMG do músculo masseter foi estatisticamente maior que a da porção anterior do músculo temporal


Subject(s)
Humans , Male , Female , Child , Malocclusion, Angle Class II/therapy , Masseter Muscle/physiology , Temporal Muscle/physiology , Dentition, Mixed , Electromyography , Mouth Rehabilitation , Orthodontic Appliances, Functional , Time Factors
17.
Braz. dent. j ; 12(3): 215-218, set.-dez. 2001. ilus, CD-ROM
Article in English | LILACS, BBO | ID: biblio-872592

ABSTRACT

O objetivo deste estudo foi relatar um caso clínico de uma prótese parcial fixa metalocerâmica sem colar metálico. Os preparos foram realizados a um nível levemente supragengival, um procedimento que é favorável aos tecidos gengivais. A ausência do colar metálico na face vestibular dos pilares oferece uma exelente aparência estética. O uso de uma prótese parcial fixa metalocerâmica sem colar metálico é um método viável para restaurar a dentição onde a qualidade estética for de fundamental importância


Subject(s)
Humans , Female , Adult , Denture Design , Denture, Partial, Fixed , Esthetics, Dental , Metal Ceramic Alloys
18.
Rev. bras. odontol ; 57(3): 151-4, maio-jun. 2000. ilus
Article in Portuguese | LILACS, BBO | ID: lil-283542

ABSTRACT

Este trabalho relata um caso clínico de perda de dimensäo vertical levando à falência morfológica, funcional e estética. Através de métodos fonéticos, de mensuraçäo facial e fotográficos determinou-se uma dimensäo vertical de oclusäo satisfatória, a qual serviu de ponto de partida para a execuçäo da reabilitaçäo protética do paciente


Subject(s)
Humans , Female , Adult , Dental Prosthesis , Denture, Partial, Fixed , Denture, Partial, Removable , Vertical Dimension , Esthetics, Dental
19.
Rev. odontol. Univ. Säo Paulo ; 13(3): 283-7, jul.-set. 1999. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-256070

ABSTRACT

O objetivo deste trabalho foi comparar in vitro a alteraçäo de temperatura na superfície radicular externa durante o preparo para contençäo intra-radicular utilizando 4 técnicas de remoçäo da guta-percha: condensadores aquecidos, brocas de Peeso, Gates-Glidden e Largo, em 40 dentes pré-molares inferiores (unirradiculares) tratados endodonticamente. Experimento foi realizado em uma câmara com temperatura controlada em torno de 26ºC. Para a remoçäo da guta-percha do interior dos canais, foram calculados dois terços do comprimento da raiz, deixando em torno de 4 mm de obturaçäo apical. As mediçöes da temperatura radicular externa foram realizadas com um termopar acoplado a um multímetro e efetuadas em 3 regiöes: cervical (em torno de 3 mm abaixo da junçäo cemento-esmalte), média e apical...


Subject(s)
Post and Core Technique , Gutta-Percha , Body Temperature Changes , In Vitro Techniques , Root Canal Preparation/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL